1 | 32- Directed Donation Process | - The establishment did not always perform donor screening for directed donors in accordance with the requirements set out in the Directive.
- The establishment’s structured donor screening questionnaire for directed donors did not include some criteria outlined in the directive.
|
2 | 35- Directed Donation Process | - The primary establishment did not always ensure that a repeat donor was reassessed in accordance with the Directive.
|
3 | 43- Quality Management System | - The establishment’s document control or records management system was not sufficient.
|
4 | 43- Quality Management System | - Some standard operating procedures were not always followed.
|
5 | 44- Quality Management System | - Not all standard operating procedures were in a standard format
|
6 | 44- Quality Management System | - Some processes were not described in standard operating procedures.
|
7 | 44- Quality Management System | - Some standard operating procedures were not kept up to date.
|
8 | 53- Personnel, Facilities, Equipment and Supplies | - The establishment’s program for the initial and ongoing training of some personnel and for evaluating their competency was not sufficient.
|
9 | 58- Personnel, Facilities, Equipment and Supplies | - The expiry dates of critical supplies were not always observed.
|
10 | 59- Errors and Accidents | - The establishment’s system for error and accidents did not meet some of the requirements.
|
11 | 67- Errors and Accidents | - The establishment or health professional did not send to Health Canada a preliminary report within 72 hours after the start of investigations.
|
12 | 84- Records | - The establishment’s records were not always accurate, complete, legible and/or indelible.
|